2019

9 Woodside Rd

Greenwich, CT
  • 2019New Construction

    Construct an inground spa and required safety barrier under the 2015 IRC and 2018 Connecticut amendments. Fencing and safety devices must comply with the State Building Code. State education fee paid: $20.80. Electrical: 6 devices installed; wire pool/spa; existing pool; new spa, 2 motors, 2 lights.

    $80K
Satellite view of 104 Stonehedge Dr N No, Greenwich, CTSatellite view
2019

104 Stonehedge Dr N No

Greenwich, CT
  • 2019Pool

    Construct an inground swimming pool and required safety barrier. Fencing and safety devices must comply with the State Building Code. State education fee paid: $23.66. Per Section AG 106.1 of the CSBC and Section 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of covers/grates and suction entrapment avoidance systems (including SRVS devices) and components shall be performed, and they shall be replaced by a person licensed (CT SPB or SB1 license) in accordance with applicable manufacturer's instructions and CT State codes.

    $91.3K
Satellite view of 83 Oneida Dr, Greenwich, CTSatellite view
2019

83 Oneida Dr

Greenwich, CT
  • 2019Pool

    2015IRC/2018 CT AMEND Construct Inground Swimming Pool and Required Safety Barrier. Fencing/safety devices must comply with State Building Code. State Ed Fee paid. $39 Amend #1: 12.6.19 val $25,000 fee $371.50 add spa to pool PER SECT. AG 106.1 CSBC and Sect. 4.3, apsp-7, any pool, spa, or hot tub with a broken, loose or missing suction outlet cover shall be immediately placed out of service until repairs or replacement is completed with an approved outlet cover. In accordance with Section 6.1 of APSP-7 Standard, periodic evaluation, testing and maintenance of cover/grates and suction entrapment avoidance systems [including SRVS devices] and components shall be evaluated, maintained and replaced by a person licensed [CT SPB or SB1 license] in accordance with applicable manufacturer's instructions and CT State codes.

    $150K
Satellite view of 371 Stanwich Rd, Greenwich, CTSatellite view
2019

371 Stanwich Rd

Greenwich, CT
  • 2019Addition

    Elevated water feature off existing deck. State education fee paid: $9.10.

    $35K
Satellite view of 78 Doubling Rd, Greenwich, CTSatellite view
2019

78 Doubling Rd

Greenwich, CT
  • 2019BUI ADD ACCE

    Outdoor freestanding pergola, 10' x 36'2", over gravel. State education fee paid: $15.60.

    $60K
Satellite view of 5 Old Round Hill Ln, Greenwich, CTSatellite view
2019

5 Old Round Hill Ln

Greenwich, CT
  • 2019New Construction

    Pergola on top of the already existing granite patio. State education fee paid: $10.40.

    $40K
Satellite view of 44 Upland Dr, Greenwich, CTSatellite view
2017

44 Upland Dr

Greenwich, CT
  • 2017Pool

    Construct an inground swimming pool and required safety barrier under the 2012 IRC and 2016 Connecticut amendments. Fencing and safety devices must comply with the State Building Code. State education fee paid: $32.50. Under Section AG 106.1 of the CSBC and Section 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of cover/grates and suction entrapment avoidance systems, including SRVS devices, and components shall be performed, and components shall be replaced by a person licensed under a CT SPB or SB1 license, in accordance with applicable manufacturer's instructions and CT State codes.

    $125K
Satellite view of 44 Harbor Dr, Greenwich, CTSatellite view
2017

44 Harbor Dr

Greenwich, CT
  • 2017Pool

    2012IRC/2016 CT AMEND Construct Inground Swimming Pool and Required Safety Barrier. Fencing/safety devices must comply with State Building Code. State Ed Fee paid. $39 PER SECT. AG 106.1 CSBC and Sect. 4.3, apsp-7, any pool, spa, or hot tub with a broken, loose or missing suction outlet cover shall be immediately placed out of service until repairs or replacement is completed with an approved outlet cover. In accordance with Section 6.1 of APSP-7 Standard, periodic evaluation, testing and maintenance of cover/grates and suction entrapment avoidance systems [including SRVS devices] and components shall be evaluated, maintained and replaced by a person licensed [CT SPB or SB1 license] in accordance with applicable manufacturer's instructions and CT State codes.

    $150K
  • 2017Plumbing

    Supply and install the main gas supply from the gas meter to the pool pad. Supply and install a branch gas supply pipe from the pool pad to the barbecue and fire pit.