Construct a 40' x 20' gunite in-ground swimming pool with a spa inside the pool, automatic safety cover, saltwater system, and pool mechanicals. No mention of any patio work or retaining walls.
Replace the existing pool with a new inground 18' x 36' concrete swimming pool with an automatic safety cover, patio, pool equipment, and fence (replace existing and install new).
Construct an inground swimming pool and required safety barrier. Fencing and safety devices must comply with the State Building Code per 2018 CSBC and Section 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. State education fee: $20.80. Electrical: IRC; wire and bond 1 pool and spa with 1 automatic pool cover, 2 2 hp motors, 5 lights on a single-pole switch, 1 50-amp subpanel, 1 GFI outlet, 1 GFI outlet for lights, and 1 Easy Touch computer.
2015IRC/2018 CT AMEND Construct Inground Swimming Pool, Spa and Required Safety Barrier. Fencing/safety devices must comply with State Building Code PER SECT. AG 106.1 CSBC and Sect. 4.3, apsp-7, any pool, spa, or hot tub with a broken, loose or missing suction outlet cover shall be immediately placed out of service until repairs or replacement is completed with an approved outlet cover. State ed fee paid $19.50 electrical: wire and bond 1 pool and spa with 1 automatic pool cover, 2 2 hop motor, 4 light on single pole swtch., 1 50-amp subpanel, 1 gfi outlet, 1 gfi outlet for lights and 1 easy touch system IRC PLUMB: run 40 ft. Of trac pipe to pool heater.
Construct an inground swimming pool, spa, and required safety barrier. Fencing and safety devices must comply with the State Building Code per Section AG 106.1 CSBC and Section 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. State education fee paid: $32.50. Electrical: Wire and bond 1 pool and spa with 1 automatic pool cover, 2 2 hp motors, 5 lights on a single-pole switch, 1 50-amp subpanel, 1 GFI outlet, and 1 GFI outlet for lights.
2018 CT Amend: Construct an inground swimming pool and required safety barrier. Fencing and safety devices must comply with the State Building Code per 2018 CSBC and Section 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. State education fee paid: $16.90. Electrical: IRC. Wire and bond 1 pool with 1 automatic cover, 1 2 hp motor, 3 lights on a single-pole switch, 1 50-amp subpanel, 1 GFI outlet, 1 GFI outlet for lights, and 1 Easdy Touch computer system.
2018 CT Amend. Construct inground swimming pool, spa, and required safety barrier. Fencing and safety devices must comply with the State Building Code per 2018 CSBC and Sect. 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. State education fee: $20.80.
Construct inground swimming pool and required safety barrier. Fencing and safety devices must comply with the State Building Code. State education fee paid: $13.00. Electrical: Using IRC code, wire and bond swimming pool; 4 lights (no niche), 2 motors, 2 hp, 1 cover, 1 GFI, 1 50-amp Subpanel. Plumbing: Run approximately 6 ft. Of 7" black pipe from meter to pool heater.
Construct an inground swimming pool and required safety barrier under the 2012 IRC and 2016 CT amendments. Fencing and safety devices must comply with the State Building Code. State education fee paid: $13.00. Per Section AG 106.1 of the CSBC and Section 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of cover/grates and suction entrapment avoidance systems, including SRVS devices, and components shall be evaluated, maintained, and replaced by a person licensed under a CT SPB or SB1 license, in accordance with applicable manufacturer's instructions and CT State codes.