42' x 20' inground gunite pool with 54SF spa inside pool structure. Pool and spa to have ASTM F1346 compliant automatic safety cover, drainage system, and equipment pad- 1,450SF of pool patio- 2.5' HT x 24' LF retaining wall as per plans- 2.5' HT x 40' LF retaining wall as per plans- 2.5' HT x 48' LF retaining wall as per plansALSO DOING A 1,450 SQ OF PATIO.
A new 16' x 34' inground pool with an 8.5' x 6.5' spa inside the pool structure, an autocover, pool equipment, approximately 1,235 SF pool patio, and associated site work. A 2'H x 11.5LF retaining wall and a 3'H x 39LF retaining wall.
Pool is 33’ x 15’, and the separate spa is 8’ x 8’. The pool is to have an automatic cover, and the spa is to have a deluxe cover in compliance with ASTM F1346.
40' x 20' inground gunite pool with a 52 SF spa within. 1000 SF of patio. On 04/25/2022, a 500-gallon underground liquid propane tank was added to the scope of work. MTC.
And 2018 Connecticut amendments: Construct an inground swimming pool, spa, and required safety barrier. Fencing and safety devices must comply with the State Building Code per 2018 CSBC and Section 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. New swimming pool. State education fee paid: $39.00. Electrical: IRC. Wire and bond 1 pool and spa with 1 automatic pool cover, 2 2 hp motors, 3 lights on a single-pole switch, 1 50-amp subpanel, 1 GFI outlet, 1 GFI outlet for lights, 1 salt chlorine generator, and 1 Aqualink RS-8 computer system. Plumbing: connect gas to pool heater.
2015IRC/2018 CT AMEND Construct Inground Swimming Pool and Required Safety Barrier. Fencing/safety devices must comply with State Building Code. State Ed Fee paid. $19.50 PER SECT. AG 106.1 CSBC and Sect. 4.3, apsp-7, any pool, spa, or hot tub with a broken, loose or missing suction outlet cover shall be immediately placed out of service until repairs or replacement is completed with an approved outlet cover. In accordance with Section 6.1 of APSP-7 Standard, periodic evaluation, testing and maintenance of cover/grates and suction entrapment avoidance systems [including SRVS devices] and components shall be evaluated, maintained and replaced by a person licensed [CT SPB or SB1 license] in accordance with applicable manufacturer's instructions and CT State codes.
Construct an inground swimming pool, spa, and required safety barrier in accordance with the 2015 International Residential Code and 2018 Connecticut amendments. Fencing and safety devices must comply with the State Building Code. State education fee paid: $29.64. Electrical: wire pool to code; bond pool to code; LED lights.
2012IRC/2016 CT AMEND Construct Inground Swimming Pool and Required Safety Barrier. Fencing/safety devices must comply with State Building Code. State Ed Fee paid. $14.30 10.15.20 Change of contractor $40 PER SECT. AG 106.1 CSBC and Sect. 4.3, apsp-7, any pool, spa, or hot tub with a broken, loose or missing suction outlet cover shall be immediately placed out of service until repairs or replacement is completed with an approved outlet cover. In accordance with Section 6.1 of APSP-7 Standard, periodic evaluation, testing and maintenance of cover/grates and suction entrapment avoidance systems [including SRVS devices] and components shall be evaluated, maintained and replaced by a person licensed [CT SPB or SB1 license] in accordance with applicable manufacturer's instructions and CT State codes.
Construct an inground swimming pool, spa, and required safety barrier in accordance with the 2012 IRC and 2016 Connecticut amendments. Fencing and safety devices must comply with the State Building Code. State education fee paid: $26. Per Section AG 106.1 of the CSBC and Section 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of covers/grates, suction entrapment avoidance systems (including SRVS devices), and components shall be performed, and components shall be replaced, by a person licensed (CT SPB or SB1 license) in accordance with applicable manufacturer's instructions and Connecticut State codes.
Construct an inground swimming pool, spa, and required safety barrier in accordance with the 2012 IRC and 2016 Connecticut amendments. Fencing and safety devices must comply with the State Building Code. Per Section AG 106.1 of the CSBC and Section 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of covers/grates, suction entrapment avoidance systems (including SRVS devices), and components shall be performed, and covers/grates, systems, and components shall be replaced by a person licensed in accordance with applicable manufacturer’s instructions and Connecticut State codes (CT SPB or SB1 license).
2012IRC/2016 CT AMEND Construct Inground Swimming Pool and Required Safety Barrier. Fencing/safety devices must comply with State Building Code. State Ed Fee paid. $39.00 PER SECT. AG 106.1 CSBC and Sect. 4.3, apsp-7, any pool, spa, or hot tub with a broken, loose or missing suction outlet cover shall be immediately placed out of service until repairs or replacement is completed with an approved outlet cover. In accordance with Section 6.1 of APSP-7 Standard, periodic evaluation, testing and maintenance of cover/grates and suction entrapment avoidance systems [including SRVS devices] and components shall be evaluated, maintained and replaced by a person licensed [CT SPB or SB1 license] in accordance with applicable manufacturer's instructions and CT State codes electrical: using IRC code, wire/bond swimming pool with NO light niches, 1 2 hp motor, 1 1/2 hp blower, 1 1/2 hp blower, 1 1/2 hp cover, 1 GFI for light, 1 GFI outlet, 1 50-amp subpanel PLUMB: repipe gas main to new meter location; install gas regulator pool heat; install underground gas pipe from new location.
Construct an inground swimming pool and required safety barrier in accordance with the 2012 IRC, 2016 Supplement, and 2009 Connecticut amendments. Fencing and safety devices must comply with the State Building Code. State code fee paid: $41.60. Permits after 16-3600: Per Section AG 106.1 of the CSBC and Section 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of covers/grates, suction entrapment avoidance systems [including SRVS devices], and components shall be performed, and components shall be replaced, by a person licensed [CT SPB or SB1 license] in accordance with applicable manufacturer's instructions and CT State codes. HVAC: 500-gallon underground liquid propane tank and gas line to pool heater. Electrical: Using IRC code, wire and bond swimming pool with 2 2 50-watt lights, 1 GFI outlet, 1 GFI for lights, 1 swap subpanel, 1 2 hp motor, 1 pool cover.
APSP-7. Construct inground swimming pool and required safety barrier. Fencing and safety devices must comply with the State Building Code. Pool will be equipped with an approved safety cover meeting ASTM F 1346. State education fee paid: $20.80. Per Sections AG 106.1 of the CSBC and 4.3 of APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs are completed.
Using the IRC code, wire and bond the swimming pool; 3 500-watt lights, 2 2-hp motors, 1 pool/spa computer, 1 GFI outlet, and 1 GFI fan light. Per Section AG 106.1 CSBC and Section 4.3, APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs or replacement are completed with an approved outlet cover. In accordance with Section 6.1 of the APSP-7 Standard, periodic evaluation, testing, and maintenance of covers/grates and suction entrapment avoidance systems [including SRVS devices] and components shall be performed by a person licensed [CT SPB or SB1 license], in accordance with applicable manufacturer's instructions and CT State codes.
Construct inground swimming pool and required safety barrier under the 2009 IRC. Fencing and safety devices must comply with the State Building Code. State education fee: $26 per Sect. AG 106.1 CSBC and Sect. 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs are completed.
Construct an inground swimming pool and required safety barrier. Fencing and safety devices must comply with the State Building Code. State education fee paid: $21.58. Per Sect. AG 106.1 CSBC and Sect. 4.3, APSP-7, any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs are completed.
Construct an inground swimming pool under the 2009 IRC, with a required safety barrier. Fencing and safety devices must comply with the State Building Code. State education fee: $15.60 per Sect. AG 106.1 CSBC and Sect. 4.3, APSP-7. Any pool, spa, or hot tub with a broken, loose, or missing suction outlet cover shall be immediately placed out of service until repairs are completed.